Perencanaan Struktur Komposit Baja-Beton Dengan Metode Lrfd (Load And Resistance Factor Design) Ruang Kelas Lantai Iii Smk Pariwisata Labuan Bajo – Flores – Ntt

I Wayan Giatmajaya, I Gede Oka Darmayasa, Ni Ketut Sri Astati Sukawati

Abstract


Planning a steel-concrete composite structure using the LRFD (Load and Resistance Factor Design) method is a method that clearly takes into account the boundary conditions, various load factors, and resistance factors, where in this case the resistance factor is needed to maintain the possible lack of structural strength, while the factor load is used to anticipate the possibility of an overload that is formulated. This planning uses a composite structure that is focused on profile steel beams, steel deck plates, and composite columns. Dead and live loads are calculated based on the Indonesian loading regulations for 1983 buildings, while earthquake loads are calculated based on the earthquake resistance planning procedure for building and non-building structures as stipulated in SNI 1762-2012. The steel-concrete composite structure itself is calculated based on the specifications for the design of steel structure buildings using the LRFD method as stated in SNI 03-1729-2002. The structural analysis in the form of the magnitude of the force acting on the building was carried out using the SAP2000 application while the analysis of the feasibility of using the dimensions of the composite structure based on the SNI used was done manually. From the planning results, the dimensions of beam and column cross-sections for each floor plate 1, 2 and 3 are B1 250/250, B2 250/175, B3 300/150, and K1 350/350. The use of steel decks on floor plates 1, 2, and 3 uses shear connectors (studs) with a diameter of 19 mm with 40, 20, and 25 shear connectors, respectively. The joints used in the main and child beams on floors 1, 2, and 3 respectively use 19 mm diameter bolts with 4 bolts, 2 bolts, and 4 bolts respectively, while the connections to columns and beams use diameter bolts 20 mm with the number of bolts 8 pieces.

Keywords


Composite; LRFD; profile steel beam; steel deck plate; Shear Connector

Full Text:

PDF

References


Dinas, PU. 2017. Desain Spektra Indonesia

http://puskim.pu.go.id/aplikasi/desain_spektra_indonesia_2011/ (25 Juli 2019)

Gunawan, R. 1987. Tabel Profil Konstruksi Baja. Yogyakarta : Penerbit Kanisius

Khatuiistiani, U. 2003. Perencanaan Balok Komposit Menggunakan Metode LRFD. Surabaya : Universitas Wijaya Kusuma

Khafis, M. 2009. Perencanaan Struktur Baja Pada Bangunan Tujuh Lantai Sebagai Hotel. Solo : Universitas Sebelas Maret Surakarta

Mulyono, T. 2003. Teknologi Beton. Jakarta: Penerbit Andi

Muhamad, R.2010. Sambungan baut baja

http://eprints.polsriac.id/1559/6/BAB%2BABIII2B4.pdf (6 agustus 2019)

Pujianto, A. 2014. Struktur Komposit Dengan Metode LRFD (Load and Resistance Factor Design).

PPIUG-1983 Tentang Peraturan Pembebanan Indonesia Untuk Gedung

Setiawan, A. 2008. Perencanaan Struktur Baja Dengan Metode LRFD. Jakarta: Penerbit Erlangga

SNI 03 - 1729 - 2002 Tentang Perencanaan Struktur Baja Dengan Metode LRFD. Jakarta: Badan Standarisasi Nasional Indonesia (BSNI)

SNI 1762 – 2012 Tentang Tata Cara Ketahanan Gempa Untuk Struktur Bangunan Gedung dan Non Gedung. Jakarta : Badan Standarisasi Nasional Indonesia (BSNI)

Sri, Y. 2014. Perhitungan Struktur Komposit Pembangunan Ruang Kelas Baru SMP Negerri 44 Kecamatan Palaran Kota Samarinda. Samarinda : Universitas Mulawarman

Universitas Mahasaraswati Denpasar. 2018. Pedoman Tugas Akhir. Denpasar: Fakultas Teknik UNMAS




DOI: https://doi.org/10.47532/jiv.v3i2.214

Refbacks

  • There are currently no refbacks.


Creative Commons License
This work is licensed under a Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International License.

Jurnal Ilmiah Vastuwidya Indexed By :

Jurnal Ilmiah Vastuwidya site and its metadata are licensed under CC BY-SA

View My Stats